Share Latest Jun-2026 HQT-4160 DUMP with 57 Questions and Answers [Q27-Q46]

Share

Share Latest Jun-2026 HQT-4160 DUMP with 57 Questions and Answers

PDF Dumps 2026 Exam Questions with Practice Test

NEW QUESTION # 27
A customer wants to upgrade a VSP 5500 to a VSP 5600. Which two actions are required for this upgrade? (Choose two.)

  • A. Replace all the Power Supplies with more powerful ones.
  • B. Replace the CPUs on all the controller boards.
  • C. Replace all the memory DIMMs.
  • D. Replace all the controller boards.

Answer: A,D

Explanation:
Replace all the controller boards.
Upgrading from VSP 5500 to VSP 5600 requires installing new controller boards, as the 5600 uses a different and more advanced controller architecture.
Replace all the Power Supplies with more powerful ones.
The upgrade also requires replacing the power supplies with models that are compatible with and can support the power requirements of the VSP 5600 controllers.


NEW QUESTION # 28
Which three statements are correct regarding the cache configuration of VSP 5000 systems with two controller boxes (CBX)? (Choose three.)

  • A. CMG0 or CMG1 can be used as default cache.
  • B. The cache only support 128 GB DIMMs.
  • C. CMG0 must be used as default and CMG1 is optional.
  • D. Each controller pair (CTL1-CTL1, CTL2-CTL2) must have the same cache capacity.
  • E. All the DIMMs must be of the same type.

Answer: C,D,E

Explanation:
All the DIMMs must be of the same type.
Cache DIMMs are installed in groups (CMGs) of four, and all DIMMs within each group must be identical in capacity and speed to ensure correct interleave and performance.
CMG0 must be used as default and CMG1 is optional.
On each controller, you populate the CMG0 slots first - this becomes the active (default) cache and only after CMG0 is filled can you populate CMG1 for additional capacity.
Each controller pair (CTL1-CTL1, CTL2-CTL2) must have the same cache capacity.
Controllers operate in mirrored pairs and require symmetric cache configurations so that each side of the pair holds identical cache capacity for failover and data integrity.


NEW QUESTION # 29
Which three ISO files are part of the Microcode Kit for the VSP 5000 series? (Choose three.)

  • A. Microcode (R9)
  • B. Open Source Software (OSS)
  • C. Documents and Programs (DP)
  • D. Maintenance PC (MPC)
  • E. Custom Tools (CT)

Answer: A,B,C

Explanation:
Documents and Programs (DP)
This ISO contains the necessary documentation and utility programs required for microcode installation and maintenance.
Microcode (R9)
This ISO provides the actual microcode (firmware) that is installed onto the VSP 5000 series hardware.
Open Source Software (OSS)
This ISO includes open source software components required by the system or referenced during installation.


NEW QUESTION # 30
How many IP addresses should you configure to integrate a VSP 5000 series storage system on the customer public network?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

Explanation:
To integrate a VSP 5000 series storage system into the customer public network, you should configure two IP addresses - one for each Service Processor (SVP) to provide redundancy and ensure high availability for management access.


NEW QUESTION # 31
Which document is essential to review before starting the pre-installation process for a VSP 5000 storage system?

  • A. The installation site requirements
  • B. The annual maintenance contract
  • C. The latest software compatibility list
  • D. The customer service plan

Answer: A

Explanation:
Before beginning the pre-installation process for a Hitachi VSP 5000, it is crucial to review the installation site requirements. This ensures that the physical environment is suitable for the system and meets operational standards. Key factors include:
Rack space and floor loading for the storage system
Power requirements (voltage, redundancy, and distribution)
Cooling and airflow specifications
Network connectivity requirements
Environmental considerations such as humidity, temperature, and dust control Reviewing this document helps avoid delays, prevent equipment damage, and ensures a smooth installation.


NEW QUESTION # 32
Which statement is correct regarding the Interconnect Switches (ISWs) on VSP 5000 systems?

  • A. ISWs are switches that route data between nodes and they are located on each controller of the node.
  • B. ISWs are standalone, optional switches than can be used for both network and data path.
  • C. ISWs are switches that provide redundancy for data path and they are only used when the number of CBX pairs is higher than two.
  • D. ISWs are switches that route data between nodes using Hitachi Interconnect Edge and X-Path cables, and they are located on the Hitachi Service and Network Boxes (HSNBXs).

Answer: B

Explanation:
The Interconnect Switches on a VSP 5000 are delivered as standalone 1 U switch chassis that house both the PCIe "interconnect" modules (for routing data between controller nodes) and an Ethernet switch (for management/network traffic), so they serve both network and data-path roles.


NEW QUESTION # 33
How does the management software improve the operation of VSP 5000 systems?

  • A. By reducing physical maintenance needs
  • B. By increasing the energy consumption
  • C. By simplifying user access controls
  • D. By automating routine tasks

Answer: D

Explanation:
The Hitachi VSP 5000 management software provides a centralized interface to monitor, configure, and manage the storage system. One of its key benefits is automation of routine operational tasks, such as:
Creating and provisioning storage volumes
Assigning storage to hosts
Monitoring system health and generating alerts
Performing replication or backup scheduling
Rebuilding or rebalancing RAID groups automatically
Automation reduces manual intervention, minimizes errors, and improves operational efficiency.


NEW QUESTION # 34
What is the maximum raw storage capacity of the VSP 5800 model?

  • A. 8 PB
  • B. 12 PB
  • C. 16 PB
  • D. 4 PB

Answer: B

Explanation:
The Hitachi VSP 5800 is part of the enterprise storage portfolio from Hitachi Vantara. It is designed for high-performance, large-scale enterprise storage environments such as mission- critical databases and large virtualization platforms.
The system supports a maximum raw storage capacity of approximately 12 petabytes (PB) in its configuration, allowing organizations to store extremely large datasets while maintaining high performance and reliability.


NEW QUESTION # 35
You are installing a new VSP 5500 storage system. Which tool is used to install the initial license keys?

  • A. Maintenance Utility
  • B. Storage Navigator
  • C. SVP application
  • D. Webconsole

Answer: B

Explanation:
Storage Navigator is the tool used to install the initial license keys on a new VSP 5500 storage system. It provides the necessary interface for license management and activation.


NEW QUESTION # 36
Which two statements are correct regarding the "New Installation" procedure on a VSP 5000 system? (Choose two.)

  • A. A customer can make a request to Hitachi Vantara Technical Support for a "New Installation" procedure, if they want to reinitialize a system entirely so all former data will be erased.
  • B. You can perform the "New Installation" procedure if a newly installed system does not power on and the Hitachi Vantara Technical Support instructs you to do so.
  • C. Hitachi Vantara recommends not to perform the "New Installation" procedure on second-hand systems.
  • D. Customer Engineers (CEs) should always perform the "New Installation" procedure when a new unit arrives at customer site.

Answer: A,C

Explanation:
Hitachi Vantara recommends not to perform the "New Installation" procedure on second-hand systems.
Performing the "New Installation" procedure on used or second-hand systems is not recommended due to potential configuration, licensing, and warranty concerns.
A customer can make a request to Hitachi Vantara Technical Support for a "New Installation" procedure, if they want to reinitialize a system entirely so all former data will be erased.
Customers may request Technical Support to perform a "New Installation" to fully reinitialize the system, which erases all existing data and restores factory settings.


NEW QUESTION # 37
You need to add another SBX with 4 drive boxes (DBS2) and 16 drives to a VSP 5100. What is the correct procedure?

  • A. Insert the drives in the DBs. Mount the DBs in the rack and install them with the Maintenance Utility.
  • B. Mount the empty DBs in the rack. Insert the drives in the DBs and install them with the Maintenance Utility.
  • C. Mount the empty DBs in the rack and attach the cables. Install the DBs with the Maintenance Utility. Insert the drives in the DBs and install them with the Maintenance Utility.
  • D. Insert the drives in the DBs. Mount the DBs in the rack and attach the cables. Install the drives with the Maintenance Utility.

Answer: B

Explanation:
The correct procedure is to first mount the empty drive boxes (DBs) in the rack, then insert the drives into the DBs, and finally use the Maintenance Utility to install and configure the new hardware. This ensures proper detection and initialization by the system.


NEW QUESTION # 38
In a VSP 5100 a drive in a RAID5 Parity Group has failed and has been blocked by the microcode. As a result, which process gets automatically started?

  • A. Copy Back
  • B. Dynamic Sparing
  • C. Sparing Copy
  • D. Correction Copy

Answer: D

Explanation:
When a drive in a RAID5 Parity Group fails and is blocked by the microcode in a VSP 5100, the Correction Copy process is automatically started to rebuild the data onto a spare drive.


NEW QUESTION # 39
The process of 'sparing' in VSP 5000 storage systems is designed to:

  • A. Serve as a backup for the storage management software
  • B. Provide additional storage for user data
  • C. Increase the processing power of the storage controllers
  • D. Automatically replace failing drives to prevent data loss

Answer: D

Explanation:
In the Hitachi VSP 5000 enterprise storage platform, sparing refers to reserving spare disk drives that automatically take over when an active drive fails or becomes faulty.
How it works:
The storage system keeps one or more hot spare drives available.
When a disk in a RAID group fails, the system automatically assigns the spare drive.
Data is rebuilt onto the spare drive using RAID redundancy.
The RAID group returns to a protected state, minimizing risk of data loss.


NEW QUESTION # 40
What are the components involved in setting up a VSP 5000 system configuration? (Choose Two)

  • A. Management software
  • B. User interfaces
  • C. Power units
  • D. Parity Groups

Answer: A,D

Explanation:
When configuring a Hitachi VSP 5000 storage system, two key components are critical:
Parity Groups (A)
These are RAID-based groups of disks that store data and parity information.
They define how data is distributed and protected across physical drives.
Essential for creating storage pools and volumes for hosts.
Management Software (D)
Provides the interface to configure, monitor, and manage storage resources.
Tasks include:
Creating volumes/LUNs
Assigning storage to hosts
Monitoring health and performance
Managing replication and backups


NEW QUESTION # 41
A customer wants to upgrade a diskless VSP 5100 to a VSP 5500. Which three types of components will be added during the upgrade? (Choose three.)

  • A. Channel Boards (CHBs)
  • B. Hitachi Interconnect Edges (HIEs)
  • C. Hitachi Service and Network Box (HSNBX)
  • D. Controllers (CTLs)
  • E. Interconnect Switches (ISWs)

Answer: A,D,E


NEW QUESTION # 42
During the parts-replacement process on a VSP 5000 storage system, what is the recommended action before removing any component?

  • A. Documenting the serial number of the component
  • B. Notifying all connected users about the impending downtime
  • C. Isolating the power supply to the specific component
  • D. Ensuring the system is in maintenance mode

Answer: D

Explanation:
Before replacing any component in a Hitachi VSP 5000 storage system, it is critical to put the system or the affected controller/module into maintenance mode.
This ensures:
No active I/O is directed to the component being replaced.
Data integrity is preserved during the removal and replacement process.
The system prevents accidental disruptions to other parts of the storage array.
Automatic failover or rebuild processes do not interfere with the replacement.


NEW QUESTION # 43
You need to perform a microcode upgrade on a VSP 5500H and you first want to backup the configuration. How do you accomplish this task?

  • A. Use Copy Config Files under the Maintenance Utility.
  • B. Use Copy Config Files under the Initial Setting menu of the SVP GUI.
  • C. Connect the maintenance laptop to the SVP port and use Copy Config Files.
  • D. Connect a USB drive to the SVP and use Copy Config Files.

Answer: B

Explanation:
To back up the configuration before a microcode upgrade on a VSP 5500H, you should use the
"Copy Config Files" option available under the Initial Setting menu in the SVP GUI. This ensures a proper backup of system settings and configuration.


NEW QUESTION # 44
You are installing a VSP 5100. Which two DKU types are supported at level 1 in the DKU boxes?
(Choose two.)

  • A. DBS2
  • B. UBX
  • C. SBX
  • D. FBX

Answer: A,C

Explanation:
SBX
SBX (Small Box) drive enclosures are supported at level 1 in the DKU boxes for VSP 5100 systems.
DBS2
DBS2 (Drive Box S2) enclosures are also supported at level 1 in the DKU boxes for VSP 5100 systems.


NEW QUESTION # 45
Which tool is used for part replacement in a VSP 5000 system?

  • A. Storage Navigator
  • B. Hi-Track
  • C. Web Console
  • D. Maintenance Utility

Answer: D

Explanation:
The Maintenance Utility is the designated tool for performing part replacement operations in a VSP 5000 system. It provides the necessary procedures to safely block, replace, and unblock hardware components.


NEW QUESTION # 46
......


The Hitachi HQT-4160 exam is intended for IT professionals who have experience with Hitachi Vantara storage systems and who want to take their skills to the next level. Candidates who pass the exam will be able to perform a wide range of tasks related to the installation and configuration of VSP 5000 Series storage systems, including setting up the hardware, configuring the software, and troubleshooting common issues. Hitachi Vantara Qualified Professional - VSP 5000 Series Installation certification is highly valued in the IT industry and can open up new career opportunities for those who earn it.


Hitachi HQT-4160 certification exam is designed for IT professionals who have experience in installing and configuring enterprise-class storage systems. HQT-4160 exam is ideal for system administrators, storage administrators, and IT professionals who are responsible for maintaining and managing storage infrastructure. Hitachi Vantara Qualified Professional - VSP 5000 Series Installation certification exam is also suitable for professionals who are interested in advancing their careers in the field of storage technology.

 

Dumps for Free HQT-4160 Practice Exam Questions: https://www.testpassed.com/HQT-4160-still-valid-exam.html